Keep your servers up and running during a power outage with the Smart-UPS SRT 3000VA RM 120V with Network Management Card from APC. With a maximum wattage of 2700W, eight NEMA 5-20R outputs, one NEMA L5-30R output, and a pre-installed network management card, the Smart-UPS SRT 3000VA RM 120V offers ideal power protection for mid-range Windows/Linux servers, Wi-Fi applications, data network backbones, medical labs, ATM machines, cellular sites, and other business-critical systems.
The rack/tower convertible Smart-UPS SRT 3000VA RM 120V comes with a multi-color backlit LCD status display that shows current load, battery charge, output/input voltage, runtime, and battery health. Also included are Gigabit Ethernet, USB and SmartSlot interfaces, a pre-installed AP9631 network management card, audible alarms, hot-swappable batteries, an estimated three-hour recharge time, and cold-start functionality.
Switched Outlet Groups
Provides the ability to control a group of receptacles independent from the main UPS. This feature allows options such as the ability to reboot hung devices without cycling the entire UPS, shedding of non-critical loads based on various parameters, scheduling time off to conserve energy, and sequenced turn on/off.
Intelligent Battery Management
Temperature compensated charging helps to extend battery life, while advanced algorithms recommend replacement date. The UPS can inform users which batteries need to be replaced in advance and detect when additional battery packs are added.
Backlit Graphical LCD
Backlit LCD provides text in multiple languages and mimic diagrams that display modes of operation, system parameters and alarms, with the ability to configure locally. Multi-color backlighting shows normal operation while highlighting issues that need attention, allowing for users to easily identify the UPS status. Information available on the LCD includes load indicator, battery charge, output/input voltage, runtime, load, and battery health.
10/100 BASE-T Connection
Connect the device to a network using a 10/100 BASE-T connection.
Battery Failure Notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance.
ECO and Green Mode
Bypasses unused electrical components in good power conditions to help boost operating efficiency by up to 97% without sacrificing protection.
Operate without Battery
Ability to immediately protect equipment when power returns after a complete discharge of the battery.
Built-in Energy Meter
Measures energy use and displays UPS efficiency in various modes of operation for easy energy tracking.
Network Manageable
Allows management of the UPS via serial, USB, or Ethernet. Includes PowerChute software for monitoring and control, safe operating system shutdown, and energy management capabilities.
InfraStruXure Manager Compatible
Enables centralized management via the APC InfraStruXure Manager.
Plug-and-Play External Batteries
Helps to ensure clean, uninterrupted power to the loads when adding extra runtime to the UPS.
Flash Upgradeable Firmware
Lets you install maintenance releases remotely via FTP.
SmartSlot Support
Customize UPS capabilities with SmartSlot management cards.
Rack/Tower Convertible Design
Helps to protects your initial investment in the UPS when migrating from tower to rack-mount environment.
Automatic Self-Test
Periodic battery self-test helps to ensure early detection of a battery that needs to be replaced.
User-Replaceable Batteries
Helps to increase availability by allowing a trained user to upgrade and replacement the batteries, which helps to reduce Mean Time to Repair (MTTR).
Audible Alarms
Provide notification of changing utility power and UPS power conditions.
Disconnected Battery Notification
Warns when a battery is not available to provide backup power.
Predictive Failure Notification
Provides early-warning fault analysis ensuring proactive component replacement.
Intelligent Battery Management
Helps to maximize battery performance, life, and reliability through precision charging.
Scalable Runtime
Allows additional runtime to be quickly added as needed.
Automatic Restart of Loads After UPS Shutdown
Automatically starts up the connected equipment upon the return of utility power.
Hot-Swappable Batteries
Helps to ensure clean, uninterrupted power to protected equipment while batteries are being replaced.
Automatic Internal Bypass
Supplies utility power to the connected loads in the event of a UPS power overload or fault.
Temperature-Compensated Battery Charging
Helps to prolong battery life by regulating the charge voltage according to battery temperature.
Input Power Factor Correction
Minimizes installation costs by enabling the use of smaller generators and cabling.
Generator Compatible
Helps to ensure clean, uninterrupted power to protected equipment when generator power is used.
Power Conditioning
Protects connected loads from surges, spikes, lightning, and other power disturbances.
Safety-Agency Approved
Product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
Cold-Start Capability
Provides temporary battery power when the utility power is out.
Resettable Circuit Breaker
Provides easy recovery from overloads; no need to replace a fuse.
Pre-Installed Network Management Card
The included and pre-installed APC AP9631 network management card allows for remote management and monitoring of the UPS.
Additional Features and Specifications
Power cord length: 8' / 2.44m
Expected battery life: 3-5 years
RBC (Replacement Battery Cartridge) quantity: 1
Extendable Run Time: 1
Protection class: IP 20